Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown

Product Details
Customization: Available
Lubrication Style: Lubricated
Cooling System: Water Cooling
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
>2000 square meters
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
  • Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
Find Similar Products

Basic Info.

Cylinder Arrangement
Balanced Opposed Arrangement
Cylinder Position
Angular
Structure Type
Closed Type
Compress Level
Double-Stage
Refrigerant Type
LPG
Type
Zw-0.8/16-24
Power
15kw
Inlet Pressure
1.6MPa
Outlet Pressure
2.4MPa
Max Differential Pressure
0.8MPa
Dimension (mm)
1000*680*870
Capacity
48m3/H
Transport Package
Fumigation Wooden Box, by Sea
Specification
1600x1100x1400
Origin
China
HS Code
8414804090
Production Capacity
500sets/Year

Product Description

Xuzhou Huayan Gas Equipment Co.,Ltd, exporting diaphragm compressor, piston compressor, oxygen generator, gas cylinder and nitrogen generators with good quality and low price.

Piston compressor is a kind of piston reciprocating motion to make gas pressurization and gas delivery compressor mainly consists of working chamber, transmission parts, body and auxiliary parts. The working chamber is directly used to compress the gas, the piston is driven by the piston rod in the cylinder for reciprocating motion, the volume of the working chamber on both sides of the piston changes in turn, the volume decreases on one side of the gas due to the pressure increase through the valve discharge, the volume increases on one side due to the reduction of air pressure through the valve to absorb the gas.
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown


Compressor for unloading and loading
Product description
This ZW series of oil-free compressors is one of the first products produced by our factory in China. The compressors have the advantage of low rotating speed, high component strength, stable operation, long service life and convenient maintenance. It is consist of compressor, gas-liquid separator, filter, two-position four-way valve, safety valve, check valve, explosion-proof motor and base etc. It has the characteristics of small size, light weight, low noise, good sealing, easy installation and easy operation.
This compressor is mainly used for unloading, loading, dumping, residual gas recovery and residual
liquid recovery of LPG/C4, propylene and liquid ammonia. It is widely used in gas, chemical,
energy and other industries, and is a key equipment in gas, chemical, energy and other
industries.

Note: In the process of unloading, the compressor pressurizes the gas from the storage tank and then presses it into the tanker through the gas phase line, and presses the liquid from the tanker to the storage tank through the pressure difference of the gas phase to complete the unloading two process. When the gas phase is pressurized, the temperature of the gas phase will rise. At this time, it is not necessary to force it to cool, because if the gas phase is compressed and then cooled, it is easy to liquefy, and the pressure difference of the gas phase is difficult to establish, which is not conducive to the replacement of the gas phase and the liquid phase. In short, it will prolong the unloading process time. If residual gas recovery is required, during the residual gas recovery operation, a cooler can be selected for forced cooling of the gas phase, so as to recover the residual gas as soon as possible.
The loading process is the opposite of the unloading process.

Propane-Butane Mix Compressor
Number Type Power(kW) Dimension (mm) Loading or unloading (t/h)
  1.  
ZW-0.6/16-24 11 1000×680×870 ~15
  1.  
ZW-0.8/16-24 15 1000×680×870 ~20
  1.  
ZW-1.0/16-24 18.5 1000×680×870 ~25
  1.  
ZW-1.5/16-24 30 1400×900×1180 ~36
  1.  
ZW-2.0/16-24 37 1400×900×1180 ~50
  1.  
ZW-2.5/16-24 45 1400×900×1180 ~60
  1.  
ZW-3.0/16-24 55 1600×1100×1250 ~74
  1.  
ZW-4.0/16-24 75 1600×1100×1250 ~98
  1.  
VW-6.0/16-24 132 2400×1700×1550 ~147
Inlet pressure:≤1.6MPa
Outlet pressure: ≤2.4MPa
Max differential pressure: 0.8MPa
Maximum Instantaneous Pressure Ratio:≤4
Cooling method: Air cooling

The unloading volume is calculated according to the inlet pressure of 1.6MPa, the outlet pressure of 2.4MPa, the inlet temperature of 40 ºC , and the density of propylene liquid of 614kg/m3. When the working conditions change, the unloading volume will change accordingly,
which is for reference only.

 Piping and Instrumentation Diagram of gas unloading  
 Liquid delivery
At the beginning, open the liquid phase pipeline between the tanker and the storage tank. If the liquid level in the tanker is higher than the storage tank, it will automatically flow into the storage tank. When the balance is reached, the flow will stop. If the liquid phase of the tanker is lower than the storage tank, directly start the compressor, the four-way valve is in the positive position, and the gas is extracted from the storage tank by the compressor and then discharged into the tanker. At this time, the pressure in the tank car rises, the pressure in the storage tank drops, and
the liquid in the tank car flows into the storage tank. (as shown below)
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown

 Surplus liquid recovery
The residual liquid recovery process is the opposite of liquid transfer. After the liquid is delivered, the four-way valve should be reversed, and the dotted line in the figure is closed. At this time, the remaining gas in the tanker is inhaled by the compressor, pressurized and then discharged to the storage tank until the pressure of the remaining gas drops to no recovery value. When recycling, pay attention that the compressor pressure ratio and exhaust temperature cannot exceed the allowable values.

The working principle of the four-way valve
                   
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown

Pull the handle of the four-way valve, when the four-way valve is in the position shown in Figure a, the A side is the intake air, and the gas flows from A to B, through the pipe, the intake filter part, the compressor intake pipe, the compressor, The compressor discharge pipe, the D end flows to the C end, and the C end is the exhaust end.
When the four-way valve is in the position of Figure B, the C end is the intake air, and the gas flows from the C end to the B end, through the pipe, the intake filter part, the compressor intake pipe, the compressor, the compressor exhaust pipe, and the D end It flows to end A, which is the exhaust end.


Reference example for selection and calculation of Propane-Butane Mix unloading compressor
.Selection of compressor inlet and outlet pressure
Saturated vapor pressure of Propane-Butane Mix at 20~36ºC
Temperature(ºC) Atmosphere Temperature(ºC) Atmosphere
20 8.4585 30 11.512
22 9.0125 32 12.212
24 9.5940 34 12.943
26 10.2040 36 13.708
28 10.8430    
In the case of high temperature, the saturated vapor pressure of Propane-Butane Mix is high, so the 16barg (inlet pressure)-24barg (outlet pressure) model is selected to meet the use environment when the temperature is high.
Note: The unit of pressure is kg/cm2

 
  • Compressor Flow Calculation
The specific flow calculation is more complicated and needs to be finally determined according to the calculation formula and experience. Only a simple calculation method is introduced here.

1. Calculate the volume of the tanker
According to the provided operating conditions, first determine the total volume flow required to unload the 15-ton Propane-Butane Mix tanker in 1 hour.
The specific gravity of Propane-Butane Mix is 0.618, so the volume of 15 tons of Propane-Butane Mix is: 15 ÷0.618=24.272m3; and since the tanker is not allowed to be full, it is generally about 80% of the tanker's volume. The volume is 24.272+15×0.2=27.272, so the volume of the tanker should be 30m3.


2.Calculate flow
When the compressor is unloading, the pressure difference must first be established before the Propane-Butane Mix can be unloaded from the tanker to the storage tank. Generally, the time to establish the pressure difference is 15 minutes, so the actual unloading time is only about 45 minutes, that is, the required displacement is 30 ÷ 45 = 0.66667m3/min; and after the gas is pressurized from 16kg to 24kg by the compressor, the volume will be reduced to about 0.66667 (16 ÷ 24) of the original volume, then the compressor displacement is: 0.66667 ÷ 0.66667 =1m3/min

According to the above calculation, the compressor model is selected as ZW-1.1/16-24

Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown



Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm ShutdownOil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown

Shipping & Package
Oil Free Hydrogen Argon Gas Plant CNG Natural Gas Compressor with PLC Control Automatic Alarm Shutdown

FAQ
1.How to get a prompt quotation of gas compressor ?
1)Flow Rate/Capacity : ___ Nm3/h
2)Suction/ Inlet Pressure : ____ Bar
3)Discharge/Outlet Pressure :____ Bar
4)Gas Medium :_____
5)Voltage and Frequency : ____ V/PH/HZ


2.How long is delivery time ?
Delivery time is around the 30-90 days .

3.What about the voltage of products? Can they be customized?
Yes, the voltage can be customized according to your inquire.

4.Can you accept OEM orders?
Yes, OEM orders is highly welcome.

5.Will you provide some spare parts of the machines?
Yes, we will .
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier